HLM Series – Voltage Monitor Series - Littelfuse HLM Voltage Monitoring Relays Provide Superior Protection

External overview image
Roll Over to Zoom
Disclaimer Notice

Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. "Littelfuse" includes Littelfuse, Inc., and all of its affiliate entities.

The HLM (HLMU) series is a universal voltage, encapsulated, three-phase voltage monitor. This monitor continuously measures the voltage of each of the three phases with microcontroller accuracy and compares the value to preset trip points. It separately senses phase reversal and loss; over, under and unbalanced voltages; and over or under frequency. Protection is ensured during periods of large average voltage fluctuations or when regenerated voltages are present. The unit trips within 200 ms when phase loss is detected. Adjustable time delays are included to prevent nuisance tripping and short cycling of sensitive equipment. The isolated, 10 A, DPDT relay contacts trip when a phase voltage exceeds the trip limits for the trip delay. Nominal line voltage, voltage unbalance, and time delays are knob adjustable. The phase loss setpoint and the acceptable frequency range are fixed. Both delta and wye systems can be monitored - no connection to neutral is required.
See datasheet for operation details.

Features

  • Proprietary microcontroller-based circuitry
  • Universal line voltage range
  • DIN-rail (35mm) or surface mounting
  • LED indication
  • Encapsulated
  • Finger-safe terminal blocks

Access specifications, certifications, check availability and order parts below

Catalog #Input
Voltage (V)
Output
Form
Termination TypeMounting MethodDimensionsWeight (lbs/g)HumidityInput AC Line Frequency (Hz)Input Phase SequenceInput TypeInput Voltage Maximum (V)Output Load Rating (VA)Output TypeOver/Under Frequency (%)Overvoltage Reset Voltage (%)StockSamplesCompare
HLMUDLAAA200 - 240 Vac; 340 - 420 Vac; 400 - 480 VacDPDTScrew terminal connection for up to #12 AWG (3.3 mm²) wireSurface mount with one #10 (M5 x 0.7) screw3 H x 2 W x 1.64 D in. (76.7 x 50.8 x 41.7 mm)0 Kg95% non-condensing50 / 60 automatically detected; 240 V ac: 50 / 60; 380 V ac: 50; 480 V ac: 60A; B; C; L1; L2; L33-phase delta or WYE with no connection to neutral55010 A resistive @ 240 Vac; 8 A resistive @ 277 Vac; NO-1/4 hp @ 120 Vac; 1/3 hp @ 240 VacIsolated electromechanical relay±4%; Reset ±3%; 50 / 60 Hz≅-3% of the trip voltageCheckOrder
HLMUDN0405N200 - 240 Vac; 340 - 420 Vac; 400 - 480 VacDPDTScrew terminal connection for up to #12 AWG (3.3 mm²) wireSurface mount with one #10 (M5 x 0.7) screw3 H x 2 W x 1.64 D in. (76.7 x 50.8 x 41.7 mm)0 Kg95% non-condensing50 / 60 automatically detected; 240 V ac: 50 / 60; 380 V ac: 50; 480 V ac: 60A; B; C; L1; L2; L33-phase delta or WYE with no connection to neutral55010 A resistive @ 240 Vac; 8 A resistive @ 277 Vac; NO-1/4 hp @ 120 Vac; 1/3 hp @ 240 VacIsolated electromechanical relay±4%; Reset ±3%; 50 / 60 Hz≅-3% of the trip voltageCheckOrder
HLMUDNAAN200 - 240 Vac; 340 - 420 Vac; 400 - 480 VacDPDTScrew terminal connection for up to #12 AWG (3.3 mm²) wireSurface mount with one #10 (M5 x 0.7) screw3 H x 2 W x 1.64 D in. (76.7 x 50.8 x 41.7 mm)0 Kg95% non-condensing50 / 60 automatically detected; 240 V ac: 50 / 60; 380 V ac: 50; 480 V ac: 60A; B; C; L1; L2; L33-phase delta or WYE with no connection to neutral55010 A resistive @ 240 Vac; 8 A resistive @ 277 Vac; NO-1/4 hp @ 120 Vac; 1/3 hp @ 240 VacIsolated electromechanical relay±4%; Reset ±3%; 50 / 60 Hz≅-3% of the trip voltageCheckOrder
HLMUDRAAA200 - 240 Vac; 340 - 420 Vac; 400 - 480 VacDPDTScrew terminal connection for up to #12 AWG (3.3 mm²) wireSurface mount with one #10 (M5 x 0.7) screw3 H x 2 W x 1.64 D in. (76.7 x 50.8 x 41.7 mm)0 Kg95% non-condensing50 / 60 automatically detected; 240 V ac: 50 / 60; 380 V ac: 50; 480 V ac: 60A; B; C; L1; L2; L33-phase delta or WYE with no connection to neutral55010 A resistive @ 240 Vac; 8 A resistive @ 277 Vac; NO-1/4 hp @ 120 Vac; 1/3 hp @ 240 VacIsolated electromechanical relay±4%; Reset ±3%; 50 / 60 Hz≅-3% of the trip voltageCheckOrder
Part # Part Description RoHS Pb-free RoHS (2015/ 863/EU) Certificate REACH (SVHC’s) Declaration Halogen Free REACH (SVHC’s) IPC-Material Declaration
HLMUDRAAA 3 PHASE VOLTAGE MONITOR RoHS No 03/08/2021 PbFree No 03/08/2021 CoC_RoHS9_HLMUDRAAA Yes
03/08/2021
If the product environmental information that you are looking for does not appear in this tab,
please complete the Product Environmental Information Request Form.