RLD60 Series - RLD60 Series - Radial Leaded Polymer PTC 60 V

pRLD60
These 60V RLDs were designed to be generalpurpose resettable fuses. As such, they are capable of protecting a large variety of circuits, including power supplies, speakers, security and alarm systems, certain motors etc.

Access specifications, certifications, check availability and order parts below

Catalog #IHold (A)ITRIP
(A)
Max Volts
(V)
IMAX
(A)
PDMAX
(W)
RMIN
(Ω)
R1max
(Ω)
Max
Time
To
Trip
(A)
Max
Time
to
Trip Time
(Sec)
MountingStockSamplesCompare
RLD60P010X
Obsolete: 2007-01-01
Replaced By: 60R010XPR
0.10.260400.382.57.50.54Through HoleCheckOrder
RLD60P017X
Obsolete: 2007-01-01
Replaced By: 60R017XPR
0.170.3460400.483.380.853Through HoleCheckOrder
RLD60P020X
Obsolete: 2007-01-01
Replaced By: 60R020XPR
0.20.460400.411.834.412.2Through HoleCheckOrder
RLD60P025X
Obsolete: 2007-01-01
Replaced By: 60R025XU
0.250.560400.451.2531.252.5Through HoleCheckOrder
RLD60P030X
Obsolete: 2007-01-01
Replaced By: 60R030XU
0.30.660400.490.882.11.53Through HoleCheckOrder
RLD60P040X
Obsolete: 2007-01-01
Replaced By: 60R040XU
0.40.860400.560.551.2923.8Through HoleCheckOrder
RLD60P050X
Obsolete: 2007-01-01
Replaced By: 60R050XU
0.5160400.770.51.172.54Through HoleCheckOrder
RLD60P065X
Obsolete: 2007-01-01
Replaced By: 60R065XU
0.651.360400.880.310.723.255.3Through HoleCheckOrder
RLD60P075X
Obsolete: 2007-01-01
Replaced By: 60R075XPR
0.751.560400.920.250.63.756.3Through HoleCheckOrder
RLD60P090X
Obsolete: 2007-01-01
Replaced By: 60R090XU
0.91.860400.990.20.474.57.2Through HoleCheckOrder
RLD60P110X
Obsolete: 2007-01-01
Replaced By: 60R110XU
1.12.260401.50.150.385.58.2Through HoleCheckOrder
RLD60P135X
Obsolete: 2007-01-01
Replaced By: 60R135XF
1.352.760401.70.120.36.759.6Through HoleCheckOrder
RLD60P160X
Obsolete: 2007-01-01
Replaced By: 60R160XMR
1.63.260401.90.090.22811.4Through HoleCheckOrder
RLD60P185X
Obsolete: 2007-01-01
Replaced By: 60R185XF
1.853.760402.10.080.199.2512.6Through HoleCheckOrder
RLD60P250X
Obsolete: 2007-01-01
Replaced By: 60R250XF
2.5560402.50.050.1312.515.6Through HoleCheckOrder
RLD60P300X
Obsolete: 2007-01-01
Replaced By: 60R300XF
3660402.80.040.11519.8Through HoleCheckOrder
RLD60P375X
Obsolete: 2007-01-01
Replaced By: 60R375XH
3.757.560403.20.030.0818.7524Through HoleCheckOrder