JLLS Series - UL Class T Fast-Acting Fuse

External overview image
Roll Over to Zoom

Space-saving Class T fuses are the most compact fuses available in ratings above 30 amperes — less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide fast-acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection.

For motor and general purpose circuits where space is not critical, we recommend POWR-PRO™ JTD_ID Indicator series, LLNRK/LLSRK series, or FLSR_ID Indicator series.

Applications:

  • Protection of individual electric services and meters.
  • Main switches containing Class T fuses may be used to provide compact protection for meter stacks.
  • Molded case circuit breaker load centers and panelboards have increased interrupting ratings when “series rated” with Littelfuse Class T fuses. Refer to panelboard manufacturers’ literature for UL Listed combination of fuses and panelboards.
  • Series ratings up to 200,000 amperes are available.

Space Saving:

  • Typical three-pole Class T fuse blocks require less than 50% of the panel area required for Class R fuse blocks. Switch enclosures, fuse pullouts, and other equipment using Class T fuses are often correspondingly more compact.

Safety:

  • 200,000 A.I.R. — Reliable interruption of all overcurrents up to 200,000 amperes.
  • Extremely current limiting — Stops damaging short circuit current faster than any mechanical protective device.
  • Fast-Acting — Provides fast-acting overload protection to equipment such as variable speed drives, rectifiers and other equipment containing surge-sensitive components.

Longer Equipment Life:

  • Current limiting design greatly reduces damage to equipment caused by heating and magnetic effects of short circuit currents.

Economical:

  • Extremely current limiting design often permits use of readily available, less costly equipment.
  • Used as input or output fuses for surge-sensitive components, such as variable speed drives and rectifiers, fast-acting Class T JLLS fuses may prevent opening of expensive semiconductor fuses protecting individual components.

Access specifications, certifications, check availability and order parts below

Catalog #Amps (A)VAC (V)VDC (V)Interrupting RatingOpeningSizeStockSamplesCompare
JLLS001160030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS002260030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS003360030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS006660030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS0101060030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS0151560030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS0202060030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS0252560030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS0303060030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS03535600300200 kA @ 300 VacFast-Acting (F)Industrial CartridgeCheckOrder
JLLS0404060030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS0454560030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS0505060030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS0606060030020 kA @ 300 VdcFast-Acting (F)Industrial CartridgeCheckOrder
JLLS0707060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS0808060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS0909060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS10010060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS11011060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS12512560030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS15015060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS17517560030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS20020060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS22522560030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS25025060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS30030060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS35035060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS40040060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS45045060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS50050060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS60060060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS700700600300200 kA @ 300 VacFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS80080060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS90090060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS1000100060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS1100110060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder
JLLS1200120060030020 kA @ 300 VdcFast-Acting (F)Knife-Blade/Bolt-InCheckOrder

  • Showing 2 items
Part # Part Description RoHS Pb-free RoHS (2015/ 863/EU) Certificate REACH (SVHC’s) Declaration Halogen Free REACH (SVHC’s)
JLLS001.T FUS 600V F/A CLASS T 1A RoHS No 08/31/2006 PbFree No No
JLLS001.TXP FUS 600V F/A CLASS T 1A PLTD RoHS No 08/31/2006 PbFree No No
JLLS002.T FUS 600V F/A CLASS T 2A RoHS No 08/31/2006 PbFree No No
JLLS002.TXP FUS 600V F/A CLASS T 2A PLTD RoHS No 08/31/2006 PbFree No No
JLLS003.T FUS 600V F/A CLASS T 3A RoHS No 08/31/2006 PbFree No No
JLLS003.TXP FUS 600V F/A CLASS T 3A PLTD RoHS No 08/31/2006 PbFree No No
JLLS006.T FUS 600V F/A CLASS T 6A RoHS No 08/31/2006 PbFree No No
JLLS006.TXP FUS 600V F/A CLASS T 6A PLTD RoHS No 08/31/2006 PbFree No No
JLLS010.T FUS 600V F/A CLASS T 10A RoHS No 08/31/2006 PbFree No 08/31/2006 REACH191_Declaration_JLLS010.T_08-14-2018 No
Does not Contain
JLLS010.TXP FUS 600V F/A CLASS T 10A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS015.T FUS 600V F/A CLASS T 15A RoHS No 08/31/2006 PbFree No No
JLLS015.TXP FUS 600V F/A CLASS T 15A PLTD RoHS No 08/31/2006 PbFree No No
JLLS020.T FUS 600V F/A CLASS T 20A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS020.T_10-14-2019 REACH201_Declaration_JLLS020.T_10-14-2019 No
Does not Contain
JLLS020.TXP FUS 600V F/A CLASS T 20A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS025.T FUS 600V F/A CLASS T 25A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS025.T_09-12-2018 REACH191_Declaration_JLLS025.T_09-12-2018 No
Does not Contain
JLLS025.TXP FUS 600V F/A CLASS T 25A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS030.T FUS 600V F/A CLASS T 30A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS030.T_12-10-2020 REACH209_Declaration_JLLS030.T_12-09-2020
Does not Contain
JLLS030.TXP FUS 600V F/A CLASS T 30A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006
JLLS045.T FUS 600V F/A CLASS T 45A RoHS No 05/09/2006 PbFree No No
JLLS045.TXP FUS 600V F/A CLASS T 45A PLTD RoHS No 05/09/2006 PbFree No No
JLLS050.T FUS 600V F/A CLASS T 50A RoHS No 05/09/2006 PbFree No 05/09/2006 CoC_RoHS10_JLLS050.T_02-05-2020 REACH205_Declaration_JLLS050.T_02-05-2020 No
Does not Contain
JLLS050.TXP FUS 600V F/A CLASS T 50A PLTD RoHS No 05/09/2006 PbFree No 05/09/2006 No
JLLS060.T FUS 600V F/A CLASS T 60A RoHS No 05/09/2006 PbFree No CoC_RoHS10_JLLS060.T_01-04-2021 REACH209_Declaration_JLLS060.T_01-06-2021 No
Does not Contain
JLLS060.TXP FUS 600V F/A CLASS T 60A PLTD RoHS No 05/09/2006 PbFree No No
JLLS070.V FUS 600V F/A CLASS T 70A RoHS No 08/31/2006 PbFree No CoC_RoHS10_JLLS070.V_01-04-2021 REACH209_Declaration_JLLS070.V_01-06-2021 No
Does not Contain
JLLS070.VXP FUS 600V F/A CLASS T 70A PLTD RoHS No 08/31/2006 PbFree No No
JLLS080.V FUS 600V F/A CLASS T 80A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS080.V_10-10-2019 REACH201_Declaration_JLLS080.V_10-10-2019 No
Does not Contain
JLLS080.VXP FUS 600V F/A CLASS T 80A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS090.V FUS 600V F/A CLASS T 90A RoHS No 08/31/2006 PbFree No CoC_RoHS10_JLLS090.V_01-04-2021 REACH209_Declaration_JLLS090.V_01-06-2021 No
Does not Contain
JLLS090.VXP FUS 600V F/A CLASS T 90A PLTD RoHS No 08/31/2006 PbFree No No
JLLS100.V FUS 600V F/A CLASS T 100A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS100.V_10-14-2019 REACH201_Declaration_JLLS100.V_10-14-2019 No
Does not Contain
JLLS100.VXP FUS 600V F/A CLASS T 100A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS110.X FUS 600V F/A CLASS T 110A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS110.X_11-11-2020 REACH209_Declaration_JLLS110.X_11-11-2020
Does not Contain
JLLS110.XXP FUS 600V F/A CLASS T 110A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006
JLLS125.X FUS 600V F/A CLASS T 125A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS125.X_10-02-2020 REACH209_Declaration_JLLS125.X_10-02-2020 No
Does not Contain
JLLS125.XXP FUS 600V F/A CLASS T 125A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS150.X FUS 600V F/A CLASS T 150A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS150.X_10-10-2019 REACH201_Declaration_JLLS150.X_10-10-2019 No
Does not Contain
JLLS150.XXP FUS 600V F/A CLASS T 150A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS150.XXSC FUS 600V F/A CLASS T 150A W/SPL CRIMP RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS175.X FUS 600V F/A CLASS T 175A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS175.X_07-08-2019 REACH209_Declaration_JLLS175.X_10-02-2020 No
Does not Contain
JLLS175.XXP FUS 600V F/A CLASS T 175A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS200.X FUS 600V F/A CLASS T 200A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS200.X_05-30-2019 REACH209_Declaration_JLLS200.X_10-02-2020 No
Does not Contain
JLLS200.XXP FUS 600V F/A CLASS T 200A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS225.X FUS 600V F/A CLASS T 225A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS225.X_08-09-2019 REACH209_Declaration_JLLS225.X_10-02-2020 No
Does not Contain
JLLS225.XXP FUS 600V F/A CLASS T 225A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS250.X FUS 600V F/A CLASS T 250A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS250.X_08-09-2019 REACH209_Declaration_JLLS250.X_10-02-2020 No
Does not Contain
JLLS250.XXP FUS 600V F/A CLASS T 250A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS300.X FUS 600V F/A CLASS T 300A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS300.X_08-09-2019 REACH209_Declaration_JLLS300.X_10-02-2020 No
Does not Contain
JLLS300.XXP FUS 600V F/A CLASS T 300A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS350.X FUS 600V F/A CLASS T 350A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS350.X_08-09-2019 REACH209_Declaration_JLLS350.X_10-02-2020 No
Does not Contain
JLLS350.XXP FUS 600V F/A CLASS T 350A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS400.X FUS 600V F/A CLASS T 400A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS400.X_08-09-2019 REACH201_Declaration_JLLS400.X_08-09-2019 No
Does not Contain
JLLS400.XXP FUS 600V F/A CLASS T 400A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS450.X FUS 600V F/A CLASS T 450A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS450.X_10-14-2019 REACH201_Declaration_JLLS450.X_10-14-2019 No
Does not Contain
JLLS450.XXP FUS 600V F/A CLASS T 450A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS500.X FUS 600V F/A CLASS T 500A RoHS No 08/31/2006 PbFree No 08/31/2006 CoC_RoHS10_JLLS500.X_10-14-2019 REACH201_Declaration_JLLS500.X_10-14-2019 No
Does not Contain
JLLS500.XXP FUS 600V F/A CLASS T 500A PLTD RoHS No 08/31/2006 PbFree No 08/31/2006 No
JLLS600.X FUS 600V F/A CLASS T 600A RoHS No 08/31/2006 PbFree No No
JLLS600.XXP FUS 600V F/A CLASS T 600A PLTD RoHS No 08/31/2006 PbFree No No
JLLS700.X FUS 600V F/A CLASS T 700A RoHS No 08/31/2006 PbFree No No
JLLS700.XXP FUS 600V F/A CLASS T 700A PLTD RoHS No 08/31/2006 PbFree No No
JLLS800.X FUS 600V F/A CLASS T 800A RoHS No 08/31/2006 PbFree No No
JLLS800.XXP FUS 600V F/A CLASS T 800A PLTD RoHS No 08/31/2006 PbFree No No
JLLS900.X FUS 600V F/A CLASS T 900A RoHS No PbFree No No
JLLS900.XXP FUS 600V F/A CLASS T 900A PLTD RoHS No PbFree No No
JLLS1000X FUS 600V F/A CLASS T 1000A RoHS No PbFree No No
JLLS1000XXP FUS 600V F/A CLASS T 1000A PLTD RoHS No PbFree No No
JLLS1100X FUS 600V F/A CLASS T 1100A RoHS No PbFree No No
JLLS1100XXP FUS 600V F/A CLASS T 1100A PLTD RoHS No PbFree No No
JLLS1200X FUS 600V F/A CLASS T 1200A RoHS No PbFree No No
JLLS1200XXP FUS 600V F/A CLASS T 1200A PLTD RoHS No PbFree No No
If the product environmental information that you are looking for does not appear in this tab,
please complete the Product Environmental Information Request Form.