background-waves

PMT840004F

Product Status| Obsoletei
Obsolete Since: | 3/15/2015
Replaced By: |SL1021B400RF

PMT840004F

GP THREE ELEMENTS S.A.400V FS | Series: PMT8
info
GDT circuit protection devices dissipate electrical
surge energy safely within a contained plasma gas.
Commonly used to help protect sensitive telecom and
networking equipment and lines, GDTs protect from
damage that may result from lightning strikes and
equipment switching operations.
PropertyValue
VMIN Spark (V)
320
VNom Spark (V)
400
VMAX Spark (V)
480
Max Impulse Breakdown Voltage @ 1kV/µs (V)
1100
Capacitance (Co) (pF)
1
Impulse Discharge Current @8/20µs (kA)
10
DC Holdover Voltage (V)
135
Electrodes
3
Failsafe
Yes
MSL
MIL-STD-750D/1021
Terminations
100% Tin over Copper Clad steel
Vibration
MIL-STD-883F Method 2007.3
Humidity
MIL-STD-750D/1021
RampRate
1
  • RoHS compliant
  • Low insertion loss
  • Excellent response to fast rising transients
  • Ultra low capacitance
  • 10 kA (A suffix devices) and 20 kA (B suffix devices) surge capability tested with 8/20μs pulse as defined by IEC61000-4-5
  • Available with thermal failsafe option (add ‘F’ suffix to part number)

PMT840004F Applications

Highlights Section

  • Telecom network interfaces
  • Telephone line cards
  • Repeaters
  • Modems
  • Line test equipment

PMT840004F Resources

Showing 1 to 1 of 1 Total Results
Share
Part NumberPart DescriptionRoHSPb-FreeRoHS (2015/863/EU) CertificateREACH (SVHC's) DeclarationREACH (SVHC's)Halogen FreeIPC-Material Declaration
PMT840004FGP THREE ELEMENTS S.A.400V FSRoHS12/20/2003Pb-Free12/20/2003No

If the product environmental information that you are looking for does not appear in this tab, please complete the Product Environmental Information Request Form.