LCS Series - Current Indicator

External overview image
Roll Over to Zoom
The LCS10T12 connected to the LPM12 or LPMG12 indicator is a low cost, easy to use, go/no-go indication system for the remote monitoring of current flow. The LCS10T12 is installed on an adequately insulated wire of the monitored load. Its 12in. (30.4cm) leads are connected to the LPM12 or LPMG12 panel mount indicator directly or via customer supplied wires up to 500 feet (152.4m) long.


See datasheet to operation details.

Access specifications, certifications, check availability and order parts below

Catalog #Termination TypeWeight (lbs/g)Burden (VA)DC Resistance (Ohms)Input AC Line Frequency (Hz)Input Current Range (A)Nominal Output Current Full Range (mA)# of TurnsSensor Frequency (Hz)Sensor Hole SizeCurrent Sensor RangeStorage Temperature (F/C)StockCompare
LCS10T120 Kg≤0.50 - 20 A: 20 / 100 Hz; 21 - 50 A: 30 / 100 HzSteady 50 A turns; Inrush 300 A turns for 10s0 - 5010000.36 in. (9.14 mm) for up to #4 AWG (21.1 mm²) THHN wire-40° to 85°C (-40° to 185°F)Check
LPM1212 in. (30.4 cm) wire leads0 Kg65 Ω DC resistance of current limiter50 / 600 - 500 - 20 A: 20 - 100; 21-50A: 30-1000.36 in. (9.14 mm) for up to #4 AWG (21.1 mm²) THHN wire2 - 50 A ac; Maximum: 50 A turns continuous; Inrush 300 A turns for 10 s-40° to 85°C (-40° to 185°F)Check
LPMG1212 in. (30.4 cm) wire leads0 Kg65 Ω DC resistance of current limiter50 / 600 - 500 - 20 A: 20 - 100; 21-50A: 30-1000.36 in. (9.14 mm) for up to #4 AWG (21.1 mm²) THHN wire2 - 50 A ac; Maximum: 50 A turns continuous; Inrush 300 A turns for 10 s-40° to 85°C (-40° to 185°F)Check
LCS10T120 Kg≤0.50 - 20 A: 20 / 100 Hz; 21 - 50 A: 30 / 100 HzSteady 50 A turns; Inrush 300 A turns for 10s0 - 5010000.36 in. (9.14 mm) for up to #4 AWG (21.1 mm²) THHN wire-40° to 85°C (-40° to 185°F)Check
LPM1212 in. (30.4 cm) wire leads0 Kg65 Ω DC resistance of current limiter50 / 600 - 500 - 20 A: 20 - 100; 21-50A: 30-1000.36 in. (9.14 mm) for up to #4 AWG (21.1 mm²) THHN wire2 - 50 A ac; Maximum: 50 A turns continuous; Inrush 300 A turns for 10 s-40° to 85°C (-40° to 185°F)Check
LPMG1212 in. (30.4 cm) wire leads0 Kg65 Ω DC resistance of current limiter50 / 600 - 500 - 20 A: 20 - 100; 21-50A: 30-1000.36 in. (9.14 mm) for up to #4 AWG (21.1 mm²) THHN wire2 - 50 A ac; Maximum: 50 A turns continuous; Inrush 300 A turns for 10 s-40° to 85°C (-40° to 185°F)Check