202 200 SP Series – Single-Phase Voltage Monitor Series - Littelfuse 202 200 SP Voltage Relays/Monitors Provide Superior Protection

202-200-SP-RB-Center
Roll Over to Zoom
Disclaimer Notice

Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. "Littelfuse" includes Littelfuse, Inc., and all of its affiliate entities.

The 202 200 SP series voltage monitor is designed to protect single-phase motors regardless of their size. It can be used with 190–240 V ac, 50*/60 Hz motors to prevent damage caused by incoming power problems. A unique microcontroller-based, voltage-sensing circuit constantly monitors the voltage to detect harmful power line conditions. When a harmful condition is detected, the MotorSaver’s output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to an acceptable level and a specified amount of time has elapsed (restart delay). The trip delay prevents nuisance tripping due to rapidly fluctuating power line conditions.
*Note: 50 Hz will increase all delay timers by 20 %.

Features

  • Proprietary microcontroller-based circuitry
  • Fixed trip delay 4 s
  • Advanced LED indication
  • Adjustable restart delay (manual, 2–3 s)
  • One screw mounting and standard ¼” quick-connect terminals

Access specifications, certifications, check availability and order parts below

Catalog #Input
Voltage (V)
Output
Form
Termination TypeMounting MethodDimensionsWeight (lbs/g)HumidityInput AC Line Frequency (Hz)Input Tolerance (%)Maximum Input PowerOutput Load Rating (VA)Overvoltage Reset Voltage (%)Overvoltage Trip Voltage (%)Restart Delay RangeTrip Delay RangeStockSamplesCompare
202-200-SP190 - 240 VacSPDT0.25 in male quick connect1/4 in socket head cap screw (customer supplied)2.5 H x 2.5 W x 1.4 D in. (63.5 x 63.5 x 35.6 mm)0 Kg95% non-condensing50 / 60 (50 will increase all delay timers by 20%)±10%5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac107%110%After a Fault or Complete Power Loss: Manual; 2 - 300 s adjustableUnder/Over Voltage: 4 sCheckOrder
202-200-SP-NHV190 - 240 VacSPDT0.25 in male quick connect1/4 in socket head cap screw (customer supplied)2.5 H x 2.5 W x 1.4 D in. (63.5 x 63.5 x 35.6 mm)0 Kg95% non-condensing50 / 60 (50 will increase all delay timers by 20%)±10%5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacAfter a Fault or Complete Power Loss: Manual; 2 - 300 s adjustableUnder Voltage: 4 sCheckOrder
To request product environmental information, please complete the Product Environmental Information Request Form.