HLVA6I23 - HLVA Series

Series: HLVA
Questions? Contact Littelfuse Support
External overview image
Roll Over to Zoom
 
The HLV Series is a single-phase undervoltage monitor designed to protect sensitive equipment from brownout or undervoltage conditions. Time delays are included to prevent nuisance tripping and short cycling. The 30A, 1hp rated, SPDT relay contacts allow direct control of motors, solenoids and valves. The output relay can be ordered with isolated SPDT contact to allow monitoring of one voltage and switching a separate voltage. Two undervoltage trip point ranges allow monitoring of 110 to 120VAC or 208 to 240VAC systems.


Operation
Upon application of input voltage the output relay remains de-energized. When the input voltage value is above the pull-in voltage, the restart delay begins. At the end of the restart delay, the output relay energizes. When the input voltage falls below the trip point, the trip delay begins. If the input voltage remains below the pull-in voltage for the entire trip delay the relay deenergizes. If the input voltage returns to a value above the pull-in voltage, during the trip delay, the trip delay is reset and the relay remains energized. If the input voltage falls below the trip point voltage during the restart delay, the delay is reset and the relay remains de-energized. Reset is automatic upon correction of an undervoltage fault.
Reset: Removing input voltage resets the output relay and the time delays.

Property (Mouseover for details) Value
Input Voltage (V) Min RMS Voltage: 70 Vac; Max RMS Voltage: 264 Vac
Input AC Line Frequency (Hz) 50 / 60
Output Type Electromechanical relay
Output Form Isolated SPDT
Output Load Rating (VA) General Purpose: SPDT-NO: 125/240 Vac 30 A; SPDT-NC 15 A; Resistive: SPDT-NO: 125/240 Vac 30 A; 28 Vdc 20 A; SPDT-NC: 125/240 Vac 15 A; 28 Vdc 10 A; Motor Load: SPDT-NO: 125 Vac 1 hp; 240 Vac 2 hp; SPDT-NC: 125 Vac 1/4 hp; 240 Vac 1 hp
Time Delay Tolerance (%) ≤±5%
Reset Time (ms) ≤150 ms
Restart Delay Range 3 - 300 s adjustable
Repeat Accuracy (%) ±0.5% or 20 ms whichever is greater
Trip Delay Range 3 s
Trip Point Accuracy (%) ±3% of trip point
Undervoltage Sensing Range (V) Peak voltage sensing; 170 - 220 Vac
Power Consumption ≤4 VA
Pull-in Voltage (V) 105% or trip point voltage
Insulation Resistance ≥100
Isolation Voltage (V) ≥1500 Vrms input to output
Surge Protection IEEE C62.41-1991 Level A
Termination Type 0.25 in. (6.3 mm) male quick connect terminals
Mounting Method Surface mount with one #10 (M5 x 0.8) screw
Operating Temperature -40° to 60°C (-40° to 140°F)
Storage Temperature (F/C) -40° to 85°C (-40° to 185°F)
Humidity 95% non-condensing
Dimensions 3 H x 2 W x 1.5 D in. (76.7 x 50.8 x 38.1 mm)
Weight (lbs/g) 0 Kg
Check Stock Yes
To request product environmental information, please complete the Product Environmental Information Request Form.