background-waves

Series: 601

601 Series – Three-Phase Voltage & Frequency Monitor
Product Status| Activei
info

The 601 series is a fully-programmable voltage monitor designed to protect three-phase motors from loss of any phase (single-phasing), phase reversal, low- or high-voltage, voltage unbalance, low- or high-frequency, and rapid cycling. When a harmful condition is detected, the 601’s output relay is deactivated after the specified trip delay. The output relay reactivates after power line conditions return to an acceptable level for the programmed restart delay (RD2). This monitor can be used as a stand-alone product or networked with an RM-1000, RM-2000, PLC, computer, or SCADA system.

Eleven setpoints are viewable with the three-digit LED display or from a networked device:

  • low voltage
  • high voltage
  • voltage unbalance
  • low frequency
  • high frequency
  • RS485 address
  • trip delay for voltage/frequency faults
  • trip delay for single-phase faults
  • rapid-cycle timer (RD1)
  • restart delay after all faults (RD2)
  • type of restart after all faults (manual or automatic)

Six parameters are viewable while the motor is running:
  • L1-L2 voltage
  • L2-L3 voltage
  • L1-L3 voltage
  • average voltage
  • voltage unbalance (%)
  • frequency

When used with the RS485MS-2W communications module, the 601 can communicate with most Modbus RTU master devices. Voltage conditions can be monitored and setpoints can be changed remotely using Solutions software, an RM1000, RM2000, or other device.
  • Built-in display
  • Programmable voltage and frequency settings
  • Two programmable restart delay timers
  • Two programmable trip delay timers
  • Programmable restart control
  • Flexible reset
  • Remote display compatibility
  • Network communications capability
  • Provides real-time information and diagnostics to help with troubleshooting
  • Allows usage on wide range of systems
  • Program separate restart delay time for rapid cycle protection and motor cool down
  • One trip delay specifically for phase loss/single-phase fault condition and one trip delay for all other fault conditions
  • Choose between an adjustable automatic or manual restart to best meet individual application needs
  • Reset options include push-button on relay or remote reset with optional 777-MRSW or OL-RESET remote reset kit
  • Increases safety through remote display of real-time data and fault history without the need to open a cabinet. Aids with arc-flash safety regulations
  • Compatible with RS-485 Modbus communications module

601 Parts

FiltersFilters

601 Applications

Highlights Section

  • Oil rigs
  • Compressors and fans
  • HVAC
  • Heat, well, and sump pumps
  • Small conveyer motors