TS1 Series - Delay On Make Timer

Littelfuse Delay on Make Relays
The TS1 Series offers proven reliability and performance with years of use in OEM equipment and commercial applications. This encapsulated general use timing module is capable of controlling load currents ranging from 5mA to 1A. May be connected in series with contactors, relays, valves, solenoids, small motors, and lamps.


Operation (Delay-on-Make)
Upon application of input voltage, the time delay begins. The output is de-energized before and during the time delay. At the end of the time delay, the output energizes and remains energized until input voltage is removed.
Reset: Removing input voltage resets the time delay and output.

Access specifications, certifications, check availability and order parts below

Catalog #Input
Voltage (V)
Output
Form
Storage Temperature (F/C)Time Delay RangeSample capableCompare
TS12115024VACNO open during timing-40° to 85°C (-40°F to 185°F)150s fixedNo
TS1213024VACNO open during timing-40° to 85°C (-40°F to 185°F)30s fixedNo
TS121424VACNO open during timing-40° to 85°C (-40°F to 185°F)4s fixedNo
TS1219024VACNO open during timing-40° to 85°C (-40°F to 185°F)90s fixedNo
TS122124VACNO open during timing-40° to 85°C (-40°F to 185°F)0.05 - 3s externally adjustableNo
TS122224VACNO open during timing-40° to 85°C (-40°F to 185°F)0.5 - 60s externally adjustableNo
TS122424VACNO open during timing-40° to 85°C (-40°F to 185°F)5 - 600s externally adjustableNo
TS1311524VDCNO open during timing-40° to 85°C (-40°F to 185°F)15s fixedNo
TS132124VDCNO open during timing-40° to 85°C (-40°F to 185°F)0.05 - 3s externally adjustableNo
TS1410.25120VACNO open during timing-40° to 85°C (-40°F to 185°F)0.25s fixedNo
TS14110120VACNO open during timing-40° to 85°C (-40°F to 185°F)10s fixedNo
TS141180120VACNO open during timing-40° to 85°C (-40°F to 185°F)180s fixedNo
TS1412120VACNO open during timing-40° to 85°C (-40°F to 185°F)2s fixedNo
TS14120120VACNO open during timing-40° to 85°C (-40°F to 185°F)20s fixedNo
TS14130120VACNO open during timing-40° to 85°C (-40°F to 185°F)30s fixedNo
TS1415120VACNO open during timing-40° to 85°C (-40°F to 185°F)5s fixedNo
TS1416120VACNO open during timing-40° to 85°C (-40°F to 185°F)6s fixedNo
TS1421120VACNO open during timing-40° to 85°C (-40°F to 185°F)0.05 - 3s externally adjustableNo
TS1422120VACNO open during timing-40° to 85°C (-40°F to 185°F)0.5 - 60s externally adjustableNo
TS1423120VACNO open during timing-40° to 85°C (-40°F to 185°F)2 - 180s externally adjustableNo
TS1424120VACNO open during timing-40° to 85°C (-40°F to 185°F)5 - 600s externally adjustableNo
TS1612230VACNO open during timing-40° to 85°C (-40°F to 185°F)2s fixedNo
TS1615230VACNO open during timing-40° to 85°C (-40°F to 185°F)5s fixedNo
TS1621230VACNO open during timing-40° to 85°C (-40°F to 185°F)0.05 - 3s externally adjustableNo
TS1622230VACNO open during timing-40° to 85°C (-40°F to 185°F)0.5 - 60s externally adjustableNo