202 Series - 3-Phase Voltage/Phase Monitor

External overview image
Roll Over to Zoom
Disclaimer Notice

Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. "Littelfuse" includes Littelfuse, Inc., and all of its affiliate entities.

The 202 Series is a 3-phase, auto-ranging, dual-range voltage monitor that protects 190-480VAC, 50*/60Hz motors regardless of size. The 202-RP (and the 202-575-RP for 475-600VAC) monitors the phase rotation of 3-phase systems and trips on reverse-phase only. Critical applications include fan motors, scroll compressors, grinders, conveyor systems, elevators and escalators. Both products provide a user selectable nominal voltage setpoint and automatically select between the 200V and 400V range. This unique microcontroller-based voltage and phase-sensing device constantly monitors the 3-phase voltages to detect harmful power line conditions. When a harmful condition is detected, the MotorSaver’s output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to acceptable levels for a specified amount of restart delay time (or a manual reset). The 202 Series includes advanced single LED diagnostics. Five different light patterns distinguish between faults and normal conditions. The status light turns green and the relay is activated when rotation is correct.

Access specifications, certifications, check availability and order parts below

Catalog #Input
Voltage (V)
Output
Form
Termination TypeMounting MethodDimensionsWeight (lbs/g)Dielectric BreakdownHumidityInput AC Line Frequency (Hz)Input Phase SequenceInput Tolerance (%)Maximum Input PowerOutput Load Rating (VA)Overvoltage Reset Voltage (%)Overvoltage Trip Voltage (%)StockCompare
202190 - 480 VacSPDT0.25 in male quick connect1/4 in socket head cap screw (customer supplied)2.5 H x 2.5 W x 1.4 D in. (63.5 x 63.5 x 35.6 mm)0 Lb≥196095% non-condensing50 / 60 (50 will increase all delay timers by 20%)A; B; C±10%5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac107%110%Check
202-200-SP190 - 240 VacSPDT0.25 in male quick connect1/4 in socket head cap screw (customer supplied)2.5 H x 2.5 W x 1.4 D in. (63.5 x 63.5 x 35.6 mm)0 Kg95% non-condensing50 / 60 (50 will increase all delay timers by 20%)±10%5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac107%110%Check
202-200-SP-NHV190 - 240 VacSPDT0.25 in male quick connect1/4 in socket head cap screw (customer supplied)2.5 H x 2.5 W x 1.4 D in. (63.5 x 63.5 x 35.6 mm)0 Kg95% non-condensing50 / 60 (50 will increase all delay timers by 20%)±10%5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacCheck
202-575-RP475 - 600 VacSPDT0.25 in male quick connect1/4 in socket head cap screw (customer supplied)2.5 H x 2.5 W x 1.4 D in. (63.5 x 63.5 x 35.6 mm)0 Kg≥196095% non-condensing50 / 60 (50 will increase all delay timers by 20%)A; B; C±10%5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac107%110%Check
202-RP190 - 480 VacSPDT0.25 in male quick connect1/4 in socket head cap screw (customer supplied)2.5 H x 2.5 W x 1.4 D in. (63.5 x 63.5 x 35.6 mm)0 Kg≥196095% non-condensing50 / 60 (50 will increase all delay timers by 20%)A; B; C±10%5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac107%110%Check
To request product environmental information, please complete the Product Environmental Information Request Form.

pdficon 202 Installation Instructions

pdficon Protection Relays and Controls Catalog

pdficon Protection Relays and Controls Catalog - Spanish

pdficon Protection Relays and Controls Catalog - Mandarin

pdficon 202 NHV Installation Instructions

pdficon Fuse Accessories Selection Guide

A quick reference guide to selecting holders blocks and clips for fuse applications...

pdficon Circuit Protection Technology Application Matrix Application Guide

Littelfuse is the world leader in the design and manufacturing of fuses for the automotive industrial handheld computer and telecom markets...

pdficon Fuse Selection Guide

A quick reference guide to selecting fuses for electronic applications...

pdficon 202 Datasheet

pdficon 202 SP Installation Instructions

docicon 202-200-SP Engineering Specs

pdficon Product Selection Guide

Electronics Circuit Protection Product Selection Guide - A guide to selecting Littelfuse circuit protection components for electronic applications...

pdficon Circuit Protection Technology Application Matrix

Littelfuse is the world leader in the design and manufacturing of fuses for the automotive industrial handheld computer and telecom markets...

pdficon Fuse 202 Datasheet