The 50R single-phase voltage monitor has a voltage-sensing circuit which constantly monitors the single-phase power for a low voltage condition. Single-phase motors on fans, compressors, air conditioners, heat pumps, well pumps, sump pumps and small conveyor motors are all applicable to the Model 50R.

When a harmful condition is detected, the output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to an acceptable level and a specified amount of time has elapsed (restart delay). The trip delay prevents nuisance tripping due to rapidly fluctuating power line conditions.

Access specifications, certifications, check availability and order parts below

Catalog #Input
Voltage (V)
Output
Form
Termination TypeMounting MethodDimensionsWeight (lbs/g)HumidityInput AC Line Frequency (Hz)Maximum Input PowerOutput Load Rating (VA)Overvoltage Reset Voltage (%)Overvoltage Trip Voltage (%)Restart Delay RangeStorage Temperature (F/C)Trip Delay RangeStockCompare
50R-10095 - 120 VacSPDT - 1 Form CTorque: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacUndervoltage: 2 s; Complete Power Loss: 2 s-40° to 80°C (-40° to 176°F)4 sCheck
50R-100-295 - 120 VacSPDT - 1 Form CTorque: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacManual; 2 - 300 s-40° to 80°C (-40° to 176°F)4 sCheck
50R200190 - 240 VacSPDT - 1 Form CTorque: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacUndervoltage: 2 s; Complete Power Loss: 2 s-40° to 80°C (-40° to 176°F)4 sCheck
50R2002190 - 240 VacSPDT - 1 Form CTorque: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacManual; 2 - 300 s-40° to 80°C (-40° to 176°F)4 sCheck
50R20029190 - 240 VacSPDT - 1 Form CTorque: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac107%110%Manual; 2 - 300 s-40° to 80°C (-40° to 176°F)4 sCheck
50R2003190 - 240 VacSPDT - 1 Form CTorque: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacUndervoltage: 2 s; Complete Power Loss: 2 s-40° to 80°C (-40° to 176°F)2 - 30 sCheck
50R400380 - 480 VacSPDT - 1 Form CTorque: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 470 VA @ 600 Vac; General Purpose: 10 A @ 240 VacUndervoltage: 2 s; Complete Power Loss: 2 s-40° to 80°C (-40° to 176°F)4 sCheck
50R4002380 - 480 VacSPDT - 1 Form CTorque: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 470 VA @ 600 Vac; General Purpose: 10 A @ 240 VacManual; 2 - 300 s-40° to 80°C (-40° to 176°F)4 sCheck
50R40029380 - 480 VacSPDT - 1 Form CTorque: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 470 VA @ 600 Vac; General Purpose: 10 A @ 240 Vac107%110%Manual; 2 - 300 s-40° to 80°C (-40° to 176°F)4 sCheck
50R4003380 - 480 VacSPDT - 1 Form CTorque: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 470 VA @ 600 Vac; General Purpose: 10 A @ 240 VacUndervoltage: 2 s; Complete Power Loss: 2 s-40° to 80°C (-40° to 176°F)2 - 30 sCheck
To request product environmental information, please complete the Product Environmental Information Request Form.