SE-105 Series - Ground-Fault Ground-Check Monitor

External overview image
Roll Over to Zoom
The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.

FEATURES

BENEFITS

Adjustable pickup
(0.5, 2.0, 4.0 A)

Unit can be used on a wide variety of trailing cable applications

Adjustable time delay
(0.1 - 2.0 s)

Adjustable trip delay for quick protection and system coordination

Harmonic filter

Prevents false operation

Zener-characteristic termination assembly

Provides reliable ground-check loop verification

Fail-safe ground-check circuit

Ensures ground-check circuit remains safe even in the event of equipment failure

Conformal coating

Additional coating protects circuit boards against harsh environment

SE-105: selectable UV- or shunt-trip mode

Provides flexibility for different applications

SE-107: UV-trip mode only

Eliminates chance of unauthorized change to trip circuit

Access specifications, certifications, check availability and order parts below

Catalog #Supply
Voltage
VAC
Supply
Voltage
VDC
Relay Contacts ConfigIEEE Device NumbersRelay
Contact
Operating
DimensionsWeight (lbs/g)Auto Manual ResetConformally coatedFrequencyGF Trip Level AGF Trip Time sHarmonic FilteringReset TypeSystem typeCompare
SE-1051201 Form A (N.O.)3GC - 50G - 50N - 51G - 51NFail-safe / Non Fail-safe5.9 H x 4.3 W x 3.9 D in.0 KgAutoreset GC; Latching GFStandard50; 60; ASD0.5; 2.0; 4.00.1 - 2.0StandardFront-panel switch/Remote N.O. ContactResistance Grounded AC
SE-105D1201201 Form A (N.O.)3GC - 50G - 50N - 51G - 51NFail-safe / Non Fail-safe5.9 H x 4.3 W x 3.9 D in.0 KgAutoreset GC; Latching GFStandard50; 60; ASD0.5; 2.0; 4.00.1 - 2.0StandardFront-panel switch/Remote N.O. ContactResistance Grounded AC
SE-105DL1201201 Form A (N.O.)3GC - 50G - 50N - 51G - 51NFail-safe / Non Fail-safe5.9 H x 4.3 W x 3.9 D in.0 KgLatching GC; Latching GFStandard50; 60; ASD0.5; 2.0; 4.00.1 - 2.0StandardFront-panel switch/Remote N.O. ContactResistance Grounded AC
SE-105E2401 Form A (N.O.)3GC - 50G - 50N - 51G - 51NFail-safe / Non Fail-safe5.9 H x 4.3 W x 3.9 D in.0 KgAutoreset GC; Latching GFStandard50; 60; ASD0.5; 2.0; 4.00.1 - 2.0StandardFront-panel switch/Remote N.O. ContactResistance Grounded AC
SE-105EL2401 Form A (N.O.)3GC - 50G - 50N - 51G - 51NFail-safe / Non Fail-safe5.9 H x 4.3 W x 3.9 D in.0 KgLatching GC; Latching GFStandard50; 60; ASD0.5; 2.0; 4.00.1 - 2.0StandardFront-panel switch/Remote N.O. ContactResistance Grounded AC
SE-105L1201 Form A (N.O.)3GC - 50G - 50N - 51G - 51NFail-safe / Non Fail-safe5.9 H x 4.3 W x 3.9 D in.0 KgLatching GC; Latching GFStandard50; 60; ASD0.5; 2.0; 4.00.1 - 2.0StandardFront-panel switch/Remote N.O. ContactResistance Grounded AC

  • Showing 11 items
Part # Part Description RoHS Pb-free RoHS (2015/ 863/EU) Certificate REACH (SVHC’s) Declaration Halogen Free REACH (SVHC’s)
SE-105E GF-GC Monitor c/w 1N5339B term 240VAC RoHS No 05/03/2021 PbFree No 05/03/2021 CoC_RoHS9_SE-105E_05-03-2021 REACH197_Declaration_(Contain)_SE-105E_05-03-2021
Contains
If the product environmental information that you are looking for does not appear in this tab,
please complete the Product Environmental Information Request Form.